Modello S/AV 7 TROUBLE SHOOTING 7.1 TOO
MUCH WATER ENTERS THE BOILER ·
The
level control (tav. 06 - ref. 12) is faulty: replace the entire component
or the mercury bulb (tav. 06
- ref. 13). ·
The
level control is not perfectly regulated : re-set by means of the regulation
shaft. ·
The
floater ball of the level control (tav. 06 - ref. 17) is damaged or weighed down by calcium deposits: clean or replace. 7.2 THE ELEMENTS ARE ACTIVATED BUT THE BOILER
DOES NOT REACH PRESSURE LEVEL ·
The
heating elements (tav. 06 -
ref. 19) are cut out and no power is getting through : replace. ·
The elements circuit is cutout: check the circuit
and re-connect.. 7.3 THE
ELEMENTS ARE NOT ACTIVATED ·
The
pressure switch (tav. 06 - ref. 7) is faulty: replace. ·
The
thermal relay switch coil (tav. 07 - ref. 12) is burnt out: replace. ·
The
level control (tav. 06- ref. 12) is faulty: replace the entire component or the mercury bulb which activates the element.
·
The
electric circuit of the element is cutout : check the circuit and re-connect. 7.4 THE PRESSURE IN THE BOILER REACHES TOO HIGH
OR TOO LOW VALUES ·
The
pressure switch (tav. 06 - ref. 7) is not correctly regulated: regulate correctly by screwing/unscrewing the
regulation screw to increase/decrease pressure. ·
The
pressure switch is faulty :
replace. 7.5 THE SAFETY VALVE OPENS ·
Pressure
switch ( tav. 06 - ref. 7) set at too high values: lower the set pressure, see 7.4 ·
Pressure
switch faulty: replace. 7.6 THE PUMP DOES NOT START ·
The
level control (tav. 06 - ref. 12) is faulty: replace the entire component
or the microswitch (tav. 06
- ref. 13) which activates the pump. ·
The
electric circuit of the pump is cutout: check and re-connect ·
The
electric winding of the pump is cutout : if possible re-connect or re-wind
. ·
The
pump is blocked : unblock by
using a screwdriver on the rear of
the motor on the cooling fan
side. 7.7 THE PUMP TURNS BUT NO WATER GOES INTO THE
BOILER ·
The water solenoid valve (tav. 08 - ref. 8) or
only the coil (tav. 09 - ref.
3) is faulty : replace the damaged part. ·
There
is air in the pump fan housing : partially unscrew the cap positioned
near the water outlet pipe, let out all the air and screw up again.
·
The
check valve (tav. 08 - ref. 9) is blocked: some light taps on the valve
can re-establish functioning, if
this is not sufficient dismantle and clean. 7.8 THE
VENTILATOR DOES NOT START - VERY LITTLE AIR ·
The
motor of the built-in vacuum is burnt out ( tav. 05 - ref. 25) : replace
or re-wind. ·
Ventilation
timer (tav. 01 - ref. 6) is
faulty : replace ·
Contactor
coil ( tav. 07- ref. 12) is burnt out : replace ·
Ventilator
switch ( tav. 01- ref. 7) is faulty : replace ( this can only happen
when machine is working on manual cycle. 7.9 NO
STEAM ISSUE Steaming timer (tav. 01 - ref. 4) is
faulty : replace Steaming solenoid valve ( tav. 06 -
ref. 3) or only the coil ( tav. 10-ref. 3) is damaged : replace the defective part. Steam switch (tav. 01-ref. 3) is faulty
: replace. ( This can only happen when machine is working on manual cycle) 7.10 THE
CYCLE DOES NOT START The microswitch ( tav. 05-ref. 33)
of the start pedal is faulty : replace. The electric circuit of the pedal is
cutout : check and re-connect.
|
||||